How does UT hatch tightness testing work? A step-by-step guide
UT (ultrasonic) hatch tightness testing checks whether a ship’s hatch covers are watertight. An ultrasonic transmitter is placed inside the closed cargo hold, and a surveyor uses a handheld receiver to ‘listen’ along the hatch seals from outside. If ultrasound escapes, so could water. The strength of the signal shows how big the gap is – and exactly where it is.
New to the equipment itself? Start with what is an ultrasonic hatch cover tester?
Why test hatch covers at all?
Water getting in through leaking hatch covers is one of the main causes of cargo damage at sea. When cargo is damaged, it often leads to large claims against owners, insurers and P&I clubs.
Regular tightness testing helps ship owners, managers and surveyors find worn or damaged seals before they cause a problem. It’s also a key part of pre-loading surveys and condition surveys.

What is ultrasonic testing, in plain terms?
Ultrasound is sound at a frequency too high for people to hear. It travels through air, and it will pass through any gap that air can get through – even a very small one.
A solid, properly sealed hatch cover blocks the sound. A damaged or poorly compressed seal lets some of it out. By measuring the sound that escapes, a surveyor can find leaks without using any water at all.

What equipment do you need?
A typical ultrasonic hatch cover testing kit includes:
- A transmitter – placed inside the hold, it fills the space with a steady ultrasonic signal
- A receiver – the handheld unit the surveyor uses on deck, showing a reading on screen
- A flexible microphone and extension arm – to reach along seals and into awkward corners (the arm extends up to 1.15 m), plus a spare microphone and an emergency microphone lead
- Hard-hat compatible headphones – so the surveyor can hear the leak as well as see the reading
- A test device – to check the transmitter, microphone, extension arm and emergency lead are working before each survey
- IP66 storm-proof cases – with neck and waist straps for hands-free use on deck
- Batteries, a global charger with car adaptor and a 12–24V auxiliary power lead
Step-by-step: how is a UT hatch test carried out?
- Check the kit. Before the survey, the transmitter, microphone and extension arm are checked to make sure everything is working correctly.
- Place the transmitter in the hold. The hold can be empty or already loaded with cargo. Transmitters with emitters at several levels (upper, lower and vertical) direct more of the signal at the hatch covers. In an empty hold it sits on the floor; with cargo, it goes on top of the cargo in the centre. In a long, rectangular hold, one half of the cover is tested with the transmitter a quarter of the way along the centre line, then it is moved three-quarters of the way along for the other half.
- Take a reference reading. With the hatch opened just enough to fit the microphone through, the surveyor holds the microphone over the coaming, pointing at the transmitter, and finds the highest reading. This is the Open Hatch Value (OHV) – the benchmark that leaks are measured against. It should be at least 80 dB; a lower figure usually means the microphone is too far from the transmitter. If the cargo hatch cannot be opened, the reading can be taken through the hold access hatch. In percentage mode, the receiver is then set so this reading shows 100, and left unchanged for the rest of the survey.
- Close and secure the hatch covers. The covers should be in their normal sea-going condition, fully closed and cleated.
- Scan the seals. On deck, the surveyor moves the microphone slowly along every seal, joint and cross-joint, listening through headphones and watching the display.
- Find and measure leaks. Where ultrasound escapes, the reading rises. The higher the reading, the bigger the gap. The leak can be pinpointed to a precise spot.
- Record the results. Readings are noted in decibels (dB) or as a percentage of the Open Hatch Value, so the results can be reported and repaired.

How are the readings interpreted?
Readings can be shown in two ways. Decibels (dB) give the raw strength of the escaping signal. A percentage of the Open Hatch Value (OHV) compares each leak against a fully open hatch, which makes results easier to compare between holds and ships.
In both cases, the principle is simple: a stronger signal means a bigger gap and a more serious leak.
The widely used pass/fail guideline – set out in DNV’s approval programme for service suppliers carrying out ultrasonic hatch tightness testing, and echoed by P&I clubs such as Steamship Mutual – is:
- 0 dB – no leak: the cover is watertight
- Up to 10% of the OHV – weathertight, but not fully watertight
- Above 10% of the OHV – not weathertight; gaskets, seals or drains need attention
- 50% of the OHV or more – a significant loss of compression and an immediate lack of watertight integrity
This is why 10% of the Open Hatch Value has become the industry benchmark for weathertightness.
Why choose ultrasonic testing over a hose test?
The traditional hose test sprays water at the hatch seals and checks for water getting through. It works, but it has drawbacks. Ultrasonic testing:
- uses no water, so there’s no run-off into the port or harbour
- can be carried out with cargo already in the hold
- causes no damage to cargo
- works in sub-zero temperatures, when hose testing isn’t practical
- pinpoints the exact location and relative size of each leak
- doesn’t get in the way of other work on board
For a fuller comparison, see ultrasonic vs hose testing: which hatch cover leak test is best?

How do you choose a UT hatch testing device?
When choosing ultrasonic hatch testing equipment, surveyors usually look for:
- Type approval from a recognised classification society, such as ABS
- IACS UR Z17 compliance – UR Z17 covers on-board testing by service suppliers, and section 4.2 deals with ultrasonic leak testing
- A powerful transmitter that can fill even the largest holds
- Rugged, weatherproof construction for use on deck in all conditions
- Emitters at several levels – so the signal is aimed at the hatch covers
- A constant signal – output that stays the same throughout the battery life
- Long-term calibration and technical support
CARGO-SAFE™, designed and made in Britain by Class Instrumentation, is ABS Type Approved and complies with IACS UR Z17. Its 157 dB transmitter is suitable for any size of ship, and its units are protected to IP66. It also has three levels of emitters and constant output circuitry, and needs no special training.